Our three-state RFID e-seals report Unlocked, Locked and Tampered conditions for compatible cargo workflows. The 341 × 50 × 19 mm locking seal combines battery-assisted UHF reading, an ABS housing, galvanized steel cable and sensor functions for containers and controlled transport assets.
Three-State RFID E-Seal Specifications
The listed configuration uses a CAB1 or VBL7-NC chip, ISO 18000-6C Gen2V2 communication and an 865–868 MHz operating frequency.
| Specification | Listed Configuration | Project Requirement |
|---|---|---|
| Tag dimensions | 341 × 50 × 19 mm | Check clearance around the locking hardware. |
| Chip | CAB1 or VBL7-NC | Confirm state and sensor commands. |
| Protocol | ISO 18000-6C Gen2V2 | Verify reader firmware and software support. |
| TID or UID | 112 bits | Map the identity to the assigned cargo record. |
| EPC or Block memory | 192 bits | Define the EPC numbering structure. |
| User File_0 | 512 bits | Allocate project data before encoding. |
| Reserved memory | 112 bits | Confirm access-control requirements. |
| Operating frequency | 865–868 MHz | Confirm use in every deployment country. |
| Housing and cable | ABS housing and galvanized steel cable | Specify cable size and locking route. |
| Reference read range | Up to 25 m, reader dependent | Validate the completed reading zone. |
| Installation | Locking style | Define authorized locking and opening steps. |
| Color | Yellow; customization available | Approve visibility and printed contrast. |
| Battery | Embedded 165 mAh coin battery | Plan storage and activation control. |
| Listed endurance | Up to 12 months after locking | Include route duration and possible delays. |
| Protection | IP66 and suitable for on-metal use | Qualify the seal under actual exposure. |
| Sensors | Temperature and detection sensors | Define required data and system responses. |
| States | Unlocked, Locked and Tampered | Assign an action to every state. |
Three States, Three Operational Decisions
The state result should be evaluated together with the seal identity, assigned cargo, route stage and authorized event history.
Continue Seal Preparation
Register and assign the seal before final closure. An Unlocked result during transit requires investigation.
Verify Secured Transit
Confirm that the locked identity matches the cargo unit and the latest authorized route record.
Hold for Inspection
Compare the result with authorized opening events before permitting movement, unloading or release.
Set the Expected State by Route Stage
| Route Stage | Expected State | Verification | Action on Mismatch |
|---|---|---|---|
| Inventory issue | Unlocked | Register EPC, TID and visible serial | Remove the seal from available stock |
| Cargo assignment | Unlocked | Match seal, cargo unit and shipment | Correct the assignment before locking |
| Dispatch release | Locked | Read back identity and state | Do not release the cargo |
| Transit checkpoint | Locked | Compare identity, state, time and location | Move the unit to inspection |
| Authorized inspection | Approved opening event | Confirm authority before cable removal | Escalate the event for review |
| Destination receipt | Locked until acceptance | Match arrival with the dispatch record | Delay unloading or asset release |
Authorize Every Seal Opening
An opening workflow should establish who may remove the cable, why the seal is being opened and what replacement record must be created.
Request Access
Record the cargo unit, reason, location and person requesting the opening.
Approve the Event
Verify that the request meets the buyer's inspection or receiving rules.
Read Before Opening
Capture the existing identity and electronic state before removing the cable.
Close the Record
Record the result and assign a new seal if the cargo continues under secured custody.
Applications for Three-State E-Seals
Export Containers
Verify the assigned seal during loading, port entry, transshipment and destination receipt.
Cross-Border Transport
Compare the electronic state with customs, border and bonded-warehouse events.
Cold-Chain Cargo
Combine seal-state control with a confirmed temperature-data requirement and reader workflow.
Port Terminals
Capture seal identities at controlled lanes and direct mismatches to inspection.
Truck and Trailer Doors
Route the galvanized cable through compatible door hardware and verify it at fleet gates.
High-Value Assets
Maintain an electronic custody record for equipment and cargo with compatible locking points.
Reader and Software Requirements
| Integration Area | Requirement | Acceptance Result |
|---|---|---|
| EPC inventory | Read assigned tags within the operating zone | Correct identities reach the application |
| State commands | Support the selected chip and Gen2V2 functions | All three states are interpreted correctly |
| Sensor access | Retrieve the confirmed temperature information | Returned data matches the project definition |
| Reader events | Add time, location and reader identity | Each result has usable operational context |
| Cargo matching | Link EPC and TID with the assigned cargo | Unexpected seals create an exception |
| User permissions | Control issue, locking, opening and resolution | Every decision has an authorized operator |
Plan the Reading Zone
The reference range does not replace applied testing. Metal cargo equipment, reader antennas and route speed must be evaluated together.
Physical Layout
- Lane width and stopping position
- Seal height and orientation
- Nearby containers and barriers
- Reader-to-seal distance
Reader Configuration
- Antenna number and polarization
- Transmit-power settings
- Reader firmware version
- State-command timing
Operating Conditions
- Vehicle speed
- Number of nearby RFID tags
- Environmental exposure
- Regional frequency limits
Temperature and Battery Definition
| Requirement | Buyer Input | Verification |
|---|---|---|
| Temperature purpose | Spot check, event detection or logging requirement | Confirm the supported sensor behavior |
| Measurement range | Expected minimum and maximum temperature | Check suitability for the cargo route |
| Measurement accuracy | Permitted tolerance | Compare samples with a reference device |
| Route duration | Transit, storage and possible delay time | Compare with listed battery endurance |
| Storage period | Time before the seal is locked | Establish inventory-rotation rules |
| Alarm response | Temperature limits and escalation rules | Test the connected software response |
Qualification Before Deployment
Physical and Environmental Tests
- Fit on actual locking hardware
- Cable diameter and routing
- On-metal reading orientation
- Water, dust and handling exposure
- Controlled cable-opening test
RFID and System Tests
- Unlocked, Locked and Tampered sequence
- EPC and TID reconciliation
- Required sensor commands
- Gate reading at operating speed
- Exception and replacement workflow
Customization and Order Data
We can review physical options, visible identification and RFID encoding after the three-state workflow and reader requirements are confirmed.
Physical Configuration
- Cable diameter and length
- Yellow or customized color
- Locking-point compatibility
- Packaging and batch order
Visible Identification
- Company logo and text
- Sequential seal number
- Barcode or QR code
- Variable printed data
RFID Data
- EPC encoding structure
- TID and serial mapping
- User-memory allocation
- Encoding verification output
Information Needed for Configuration
Sealing Point
- Cargo unit and door hardware
- Locking-point photographs
- Cable dimensions and route
- Authorized opening process
Reader System
- Reader and antenna models
- Required reading distance
- State and sensor commands
- Software exception rules
Route and Order
- Operating countries
- Route and storage duration
- Artwork and encoding rules
- Quantity and delivery schedule
Related Electronic Security Seals
Compare the number of states, frequency, read range, sensor functions, battery endurance and housing dimensions before selecting another e-seal.
Three-State RFID E-Seal Questions
The listed states are Unlocked, Locked and Tampered. The reader software must retrieve each result and compare it with the expected stage of the cargo movement.
Basic EPC inventory alone may not retrieve the complete seal condition. Confirm CAB1 or VBL7-NC support, Gen2V2 commands, firmware and integration software.
The product is intended for one locking cycle. After opening or cable removal, record the event and assign a new serialized seal if secured transport continues.
No. Up to 25 m is a reader-dependent reference. Reader settings, antenna placement, metal structures, seal orientation, vehicle speed and local frequency limits affect the actual result.
Continuous logging should not be assumed from the sensor listing alone. Provide the required range, accuracy, sampling interval, storage and alarm behavior for confirmation.
The listed 165 mAh battery supports up to 12 months after locking. Storage time, operating temperature, reader activity and sensor behavior can affect achieved endurance.
Please provide the locking-point photographs, cable requirements, operating countries, route duration, reader models, three-state workflow, temperature requirements, artwork, encoding rules and quantity.
Define Your Three-State Seal Workflow
Send us the locking hardware, cable size, operating region, route duration, reader setup, state workflow, sensor requirements, artwork and quantity for review.
Request a Three-State E-Seal ReviewHot Tags: three-state rfid e-seals, China three-state rfid e-seals manufacturers, suppliers, factory, rfid seal for artificial intelligence software, rfid seal for construction, rfid seal for conveyor belts, rfid seal for hvac systems, rfid seal for laptops, rfid tamper evident seal