Our RFID E Seal combines a galvanized steel wire closure, on-metal UHF design, electronic tamper detection and temperature-sensing capability. Its 865–868 MHz configuration is intended for long-range container and cargo inspection in compatible regional deployments.
RFID E Seal Specifications
The CAB1/VBL7-NC chip provides EPC identification, user memory and sensor functions for projects requiring electronic seal status and environmental data at controlled reading points.
| Specification | Listed Configuration | Project Requirement |
|---|---|---|
| Seal dimensions | 341 × 50 × 19 mm | Check the full wire route and housing clearance. |
| RFID chip | CAB1/VBL7-NC | Confirm command support in the selected reader software. |
| TID/UID | 112 bits | Define whether TID will be recorded during issue. |
| EPC memory | 192 bits | Provide the electronic seal-number structure. |
| User memory | 512 bits in User File 0 | Define fields, encoding and update permissions. |
| Reserved memory | 112 bits | Confirm password ownership and access policy. |
| Operating frequency | 865–868 MHz | Confirm compatibility with the operating country. |
| Housing and cable | ABS housing and galvanized steel wire | Check closure holes and removal requirements. |
| Reference read range | Up to 25 m, reader dependent | Validate the installed seal in the final reading zone. |
| Installation | Tie-up, tighten, insert or lock | Document the approved locking sequence. |
| Housing color | Yellow or customized | Submit color and visible-marking requirements. |
| Mounting environment | On-metal use | Test on the actual container or equipment. |
| Sensor functions | Tamper detection and temperature sensing | Define state mapping and temperature-data use. |
Activate the Seal Through a Controlled Locking Process
The electronic seal should be issued, installed and verified as one managed event so its physical condition and digital record begin in the same state.
Assign
Link the EPC and TID with the intended container, cargo record or protected asset.
Lock
Route and secure the galvanized steel wire through the approved closure points.
Activate and Read
Confirm the expected post-lock electronic state with the selected UHF reader.
Release
Record authorization and the final electronic condition before opening the closure.
Translate Electronic States into Operating Decisions
| Inspection Event | Reader Check | System Decision | Required Follow-Up |
|---|---|---|---|
| Seal inventory | Electronic identity is valid but not assigned | Keep the seal available for controlled issue | Inspect its wire and housing before use |
| Lock confirmation | Expected activated or locked state is returned | Start the active shipment record | Confirm visible identity and cable routing |
| Transit checkpoint | EPC and state match the expected record | Accept and record the inspection event | Check for visible wire or housing damage |
| Unexpected status | The returned condition differs from the approved state | Create a controlled exception | Inspect the closure and handling history |
| Wrong EPC | Identifier does not match the assigned cargo | Prevent automatic acceptance | Compare visible and database identifiers |
| Authorized opening | The operator has approval to release the seal | Close the active electronic record | Record the final state and physical evidence |
Design a Controlled Long-Range Reading Zone
The up-to-25 m specification can support larger inspection areas, but the required seal must be separated from unrelated RFID tags and adjacent traffic.
Port Entrance
Identify the assigned electronic seal as a vehicle or container enters a controlled lane.
Container Yard
Plan antenna angles around stacked containers, metal reflections and neighboring RFID seals.
Loading Dock
Confirm identity and electronic status before cargo dispatch or warehouse acceptance.
Customs Checkpoint
Provide the electronic identity and status required by the approved inspection workflow.
Distribution Gate
Match the passing seal with the scheduled vehicle, route and shipment record.
Handheld Investigation
Use a compatible handheld reader for close inspection when a fixed point reports an exception.
Validate the Reading Zone Before Deployment
| Deployment Factor | Site Variable | Acceptance Requirement |
|---|---|---|
| Reader compatibility | Reader model, firmware and supported chip commands | Identity and sensor data are read correctly. |
| Antenna layout | Antenna gain, polarization, height and angle | The intended seal is covered throughout the lane. |
| Read-zone boundary | Adjacent lanes, stored containers and nearby tags | Unrelated seals do not create false transactions. |
| Vehicle movement | Speed, direction, stopping point and tag position | The system captures the required event reliably. |
| Metal surroundings | Container doors, bars, frames and nearby structures | The installed tag remains readable in normal use. |
| Regional settings | 865–868 MHz channels and permitted reader power | The deployment matches local operating rules. |
Define the Temperature-Sensing Requirement
Temperature sensing should be specified as a measurable project function rather than treated as continuous monitoring without defined readers, intervals and software.
Measurement Purpose
State whether temperature supports spot inspection, exception checks or another defined process.
Required Range
Provide the minimum and maximum temperatures expected during transport and storage.
Reading Schedule
Define where and when readers request temperature data from the electronic seal.
Software Response
Set the rules for recording, displaying and investigating temperature exceptions.
RFID E Seal Applications
Shipping Containers
Combine wire locking with electronic identity and status inspection during container transport.
High-Value Cargo
Associate the seal with a controlled shipment record and investigate unexpected conditions.
Customs Supervision
Support identity and seal-status checks within the authority's approved operating system.
Cold-Chain Transport
Use reader-requested temperature data where the required sensing performance has been confirmed.
Bonded Warehouses
Record seal identity and condition as controlled cargo enters or leaves storage.
Metal Equipment
Secure compatible cabinets, hatches or access points after completing on-metal testing.
Plan the Electronic and Visible Data
EPC Identification
- Customer-defined seal number
- 192-bit EPC structure
- Printed-to-EPC matching
- Encoding readback verification
User File 0
- Approved compact data fields
- Encoding within 512 bits
- Defined write permissions
- Reader-software decoding rules
Visible Identification
- Human-readable serial number
- Barcode or QR code
- Company name or logo
- Yellow or confirmed custom color
Information Needed for Configuration
Seal and Application Details
- Container, cargo or equipment type
- Closure photographs and measurements
- Wire route and housing position
- Operating and storage environment
- Installation and opening procedure
RFID and Sensor Details
- 865–868 MHz operating country
- Reader, antenna and software models
- Required tamper-state workflow
- Temperature-sensing requirements
- EPC, user data, quantity and destination
Related RFID Security Seals
Compare operating frequency, read range, sensor functions, memory, wire construction and system requirements before choosing another electronic seal.
RFID E Seal Questions
No GPS function is listed. Location and movement records are created when compatible reader infrastructure, software and site information are connected to the electronic seal identity.
No. Up to 25 m is a reference value. Reader power, antennas, metal surroundings, tag orientation, vehicle speed, interference and regional settings determine the achieved result.
The listed model operates at 865–868 MHz. Other markets require confirmation of the permitted UHF band, reader settings and availability of a suitable regional configuration.
An alert requires compatible reader infrastructure and software configured to interpret an unexpected seal state. The seal alone does not define who receives an alarm or how it is delivered.
The page lists a temperature-sensor function but does not establish continuous logging capacity. Confirm the measurement range, accuracy, reading method, interval and data storage required by the project.
A compact project-specific record can be written if it fits within 512 bits. Submit the complete field structure, encoding rules and update permissions before production programming.
A cloud platform is not inherently required. The reader may connect to a local application, private server or another approved system, depending on the buyer's architecture and integration requirements.
Please provide the closure photographs, wire route, operating country, reader and antenna models, required tamper states, temperature requirements, EPC and user data, printing, quantity and destination.
Configure the E Seal and Reading System Together
Send us the closure details, operating region, reader setup, required tamper states, temperature function, EPC and user-data format, printing and quantity for configuration review.
Request an RFID E Seal ReviewHot Tags: RFID e seal, China RFID e seal manufacturers, suppliers, factory, rfid seal for access control systems, rfid seal for connectors, rfid seal for content management software, rfid seal for conveyor belts, rfid seal for incineration, rfid seal for roofing materials