Our RFID seal tags feature a durable ABS electronic housing and a steel wire loop. Equipped with the G2IL+ chip, they offer UHF identification and anti-counterfeiting capabilities, making them suitable for containers, shipping cases, equipment, and other assets requiring high security.
RFID Seal Tag Specifications
| Specification | Listed Configuration | Project Requirement |
|---|---|---|
| Tag dimensions | 118 × 33 × 15 mm | Check the available hanging and reading area. |
| RFID chip | G2IL+ | Confirm reader support for the detection function. |
| Protocol | ISO 18000-6C Gen2 | Use compatible UHF readers and software. |
| TID/UID | 64 bits | Define whether TID is captured during commissioning. |
| EPC memory | 128 bits | Provide the electronic seal-number format. |
| User memory | 0 bits | Store assignment and history data in the backend. |
| Reserved memory | 32-bit access and 32-bit kill passwords | Define password ownership and programming controls. |
| Operating frequency | 860–960 MHz | Select the configuration for the operating region. |
| Housing | ABS plastic | Provide environmental and cleaning conditions. |
| Antenna type | Aluminum microstrip antenna | Confirm orientation near metal surfaces. |
| Standard wire | 1.5 × 300 mm replaceable steel wire | Check hole diameter and total sealing path. |
| Reference read range | Up to 6 m on metal | Test the installed tag with the intended reader. |
| Installation | Hanging style | Define housing position and cable routing. |
| Application feature | On-metal use with detection sensor | Verify all required electronic conditions. |
Single-Use Security Design
This RFID seal tag is not designed for reuse; its security relies on the integrity of the steel wire and the locking mechanism.
Once installed, the seal establishes a secure physical connection to the cargo. Removing the seal inevitably damages its structure, allowing for quick differentiation between intact and tampered seals during RFID reader inspections.
Although the internal RFID chip remains electronically readable throughout the seal's service life, this does not mean the seal itself can be reused. Once the mechanical seal has been opened, cut, or damaged, it must be replaced with a new RFID seal.
Match the Replacement Wire to the Closure
Hole Diameter
Measure the smallest opening in the complete sealing route before confirming the wire diameter.
Cable Length
Measure around the closed handles or access points and allow only the required working length.
Housing Position
Keep the RFID housing visible and away from hinges, sharp edges and moving equipment.
Authorized Removal
Define the cutting tool and removal position so the housing is not damaged unnecessarily.
Metal Orientation
Position the on-metal RFID housing consistently relative to the reader antenna.
Replacement Inventory
Keep compatible wires controlled by size, material and approved application.
Define the Record for Every Sealing Cycle
| Cycle Event | Information to Record | Required Result |
|---|---|---|
| Housing issue | EPC, TID and visible serial number | The physical and electronic identities match. |
| Asset assignment | Container, box, equipment or access point | Only one active assignment exists. |
| Wire installation | Wire size, operator, date and location | The approved closure route is secured. |
| Routine inspection | Reader result and physical wire condition | Identity and condition match the expected record. |
Plan On-Metal RFID Reading
Handheld Inspection
Use a compatible handheld reader for issue, return and close physical inspection.
Warehouse Checkpoint
Identify sealed boxes or cages moving through a controlled reader zone.
Container Reading
Test reader power, antenna angle and tag orientation on the actual metal surface.
Printing, Encoding and Replacement Options
Visible Identification
- Human-readable serial number
- Barcode or QR code
- Company name or logo
- Embossed or laser-marked text
RFID Configuration
- 128-bit EPC encoding
- TID capture where required
- Access and kill password plan
- EPC-to-print mapping file
Wire Configuration
- Standard 1.5 × 300 mm wire
- Confirmed alternative length
- Application-matched diameter
- Replacement-wire packaging
Information Needed for Configuration
Physical Application Details
- Container, box or equipment type
- Closure photographs and hole dimensions
- Required wire length and diameter
- Housing position and nearby metal
- Opening and reuse procedure
RFID and Order Details
- Destination country and UHF region
- Reader, antenna and software models
- Required detection-state workflow
- EPC format and visible artwork
- Housing and replacement-wire quantities
Related RFID Security Seals
Compare housing reuse, wire replacement, memory, detection method and reading distance before choosing another RFID seal.
RFID Seal Tag Questions
No. It is the listed standard wire. Measure the smallest hole and complete sealing path to confirm the required diameter and length for the application.
The listed G2IL+ configuration has no user memory. Store previous assignments, opening events and inspection history in a backend record linked to the EPC or TID.
No. Up to 6 m is a reference value. Reader power, antenna gain, metal geometry, tag orientation, interference and regional radio limits affect the achieved distance.
Yes. The listed G2IL+ seal tag is a passive UHF configuration powered by the reader's RF field and does not require an internal battery.
The passive tag must be interrogated by a compatible reader. The connected software decides whether the returned condition should create an exception or notification.
The product family covers 860–960 MHz, but tag tuning and reader channels should match the destination country. Provide all operating regions before confirming the configuration.
Please provide the application, closure photographs, hole and wire-path dimensions, reader models, operating countries, detection workflow, EPC format, artwork, housing quantity and replacement-wire quantity.
Configure a Reusable RFID Sealing Cycle
Send us the closure details, wire dimensions, operating region, reader setup, detection workflow, EPC format, artwork and expected reuse volume for configuration review.
Request an RFID Seal Tag ReviewHot Tags: rfid seal tag, China rfid seal tag manufacturers, suppliers, factory, rfid seal for bakery products, rfid seal for envelope, rfid seal for equipment, rfid seal for meat, rfid seal for power plants, rfid seal for supply chain