Our RFID seals for export containers combine a 421 × 50 × 19 mm ABS housing, galvanized steel cable, battery-assisted UHF communication and detection sensing. The 902–928 MHz configuration supports export container checks at loading sites, transport gates, terminals and receiving points.
RFID Export Container Seal Specifications
This larger-format configuration uses a CAB1 or VBL7-NC chip and provides up to 15 m reference reading on metal with a suitable reader installation.
| Specification | Listed Configuration | Export Project Requirement |
|---|---|---|
| Tag dimensions | 421 × 50 × 19 mm | Check door-hardware and handling clearance. |
| Antenna dimensions | 98 × 36.7 mm | Approve the installed position on metal. |
| Chip | CAB1 or VBL7-NC | Confirm identity and state functions. |
| Protocol | ISO 18000-6C Gen2V2 | Verify reader and firmware compatibility. |
| TID or UID | 112 bits | Map the chip identity to the seal record. |
| EPC or Block memory | 192 bits | Provide the required numbering structure. |
| User File_0 | 512 bits | Define fields and write permissions. |
| Reserved memory | 112 bits | Confirm access-control ownership. |
| Operating frequency | 902–928 MHz | Confirm every country where it will be read. |
| Housing and cable | ABS housing and galvanized steel cable | Specify cable size and environmental exposure. |
| Reference read range | Up to 15 m on metal | Test with the final reader and container. |
| Installation | Locking style | Approve the complete locking sequence. |
| Color | Yellow, red or green; customization available | Define color allocation and printed contrast. |
| Battery | Embedded 165 mAh coin battery | Control storage and activation records. |
| Listed endurance | Up to 12 months after activation | Include transit, storage and delay time. |
| Protection | IP66 and suitable for on-metal use | Qualify actual port and route exposure. |
| Detection | Tamper-detection sensor | Define reader commands and exception rules. |
Build the Export Sealing Record
Register
Capture the EPC, TID, visible serial, color group and production batch.
Assign
Link the seal with the container, booking, cargo, vehicle and destination.
Lock
Install the steel cable and verify the expected electronic condition.
Release
Approve dispatch only after the identity, state and export record match.
FCC-Region Export Checkpoints
The 902–928 MHz configuration is intended for compatible regional infrastructure. Every location that reads the seal must be included in route planning.
| Checkpoint | Record Compared | Expected Result | Action on Exception |
|---|---|---|---|
| Loading facility | Container, booking and assigned seal | Registered identity and Locked condition | Stop dispatch and correct the record |
| Inland transport gate | Vehicle, container and planned movement | Seal remains assigned and Locked | Route the unit to inspection |
| Export terminal | Pre-arrival and terminal booking data | Identity matches the expected container | Hold the gate transaction |
| Customs inspection | Authority and approved opening request | Opening is recorded before cable removal | Create an inspection incident |
| Transshipment location | Expected route and current seal result | No unexplained identity or state change | Hold the container for review |
| Destination receipt | Arrival and original dispatch records | Receiver approves identity and condition | Delay opening and unloading |
Validate the 15 m On-Metal Reading Zone
| Site Variable | Information Required | Acceptance Test |
|---|---|---|
| Container position | Seal height, orientation and side of approach | Read all approved installation positions |
| Reader antennas | Quantity, gain, polarization and angle | Cover the required lane without blind zones |
| Vehicle movement | Lane width, speed and stopping rules | Capture identity and condition in motion |
| Adjacent metal | Containers, barriers, buildings and equipment | Measure reflections and missed reads |
| Nearby RFID tags | Vehicle, cargo and adjacent-lane tag population | Software selects the intended container seal |
| Reader commands | Identity and detection-function timing | Retrieve all required results inside the lane |
Plan the One-Time Seal Lifecycle
Before Locking
- Inspect the housing and cable
- Verify the printed serial
- Read and register RFID data
- Assign the correct container
- Confirm the locking authority
During the Route
- Compare checkpoint identity
- Retrieve the current seal condition
- Record reader, time and location
- Investigate unexpected results
- Document authorized inspections
At End of Service
- Read before cable removal
- Record the authorized operator
- Close the shipment record
- Prevent seal reissue
- Apply the disposal procedure
Battery and Inventory Control
The listed endurance begins after activation. Storage, route duration, reader activity and operating conditions should be included in inventory planning.
Receive by Batch
Retain production, receipt and storage records for each incoming seal batch.
Rotate Inventory
Issue older approved batches first under the buyer's stock-control procedure.
Record Activation
Capture the locking or activation date with the assigned container record.
Allow for Delays
Include terminal dwell, customs holds and destination storage in route duration.
Qualification Before Volume Deployment
| Qualification Test | Method | Approval Result | Record to Retain |
|---|---|---|---|
| Container-door fit | Install the cable on actual locking hardware | Housing and cable clear moving parts | Photographs and cable dimensions |
| Identity validation | Present registered and unregistered test records | Software returns the defined result | EPC, TID and database response |
| Seal conditions | Test Unlocked, Locked and controlled opening | Every condition is interpreted correctly | Reader and event results |
| Gate reading | Move sealed containers through the planned lane | Required read rate is achieved | Speed, distance and settings |
| On-metal orientation | Test each approved housing position | Required performance remains stable | Orientation and read-rate results |
| Environmental exposure | Reproduce expected water, dust and handling | Housing and required functions remain acceptable | Exposure and inspection results |
Customization for Export Seal Programs
We can coordinate the physical configuration, visible identification and RFID data after the route and reader workflow are confirmed.
Physical Configuration
- Galvanized cable dimensions
- Yellow, red or green housing
- Custom color identification
- Locking-point compatibility
- Batch packaging sequence
Visible Identification
- Exporter or logistics logo
- Sequential seal number
- Barcode or QR code
- Route or destination text
- Variable printed data
Electronic Data
- EPC numbering structure
- TID and printed-code mapping
- User-memory allocation
- Access-setting requirements
- Encoding verification output
Information Needed for Configuration
Container Hardware
- Container and door type
- Locking-point photographs
- Cable diameter and length
- Authorized removal method
Route and Reader
- Origin, transit and destination countries
- Reader and antenna models
- Lane width and vehicle speed
- Required reading distance
Data and Order
- Identity and condition rules
- Artwork and serial-number format
- RFID encoding specification
- Quantity and delivery schedule
Related RFID Container Seals
Compare dimensions, frequency, read range, identity results, seal conditions and battery requirements before selecting another electronic seal.
RFID Export Container Seal Questions
Real or Fake should be treated as an identity-validation result. Unlocked, Locked and Tampered describe the seal condition. The system should evaluate both before releasing cargo.
Basic EPC inventory may not provide every detection function. Confirm CAB1 or VBL7-NC support, Gen2V2 commands, reader firmware and integration software.
No. Up to 15 m is a reader-dependent reference. Reader settings, antenna layout, seal orientation, surrounding metal, interference and vehicle speed affect actual performance.
No. Regional UHF rules differ. Provide every origin, transit and destination country where the seal will be read so frequency compatibility can be reviewed.
The listed locking seal is intended for one use. After authorized opening, record the final result and apply a newly registered seal if secured transport continues.
The listed 165 mAh battery supports up to 12 months after activation. Storage, temperature, reader activity, detection behavior and route duration can affect achieved endurance.
Please provide the container-door photographs, cable dimensions, complete export route, reader models, required identity and condition rules, artwork, encoding specification, quantity and delivery schedule.
Configure the Seal for Your Export Container Route
Send us the container hardware, cable dimensions, operating countries, reader deployment, identity and condition rules, artwork, encoding format and quantity for review.
Request an Export Container Seal ReviewHot Tags: rfid seals for export containers, China rfid seals for export containers manufacturers, suppliers, factory, rfid seal for artificial intelligence software, rfid seal for carts, rfid seal for forklifts, rfid seal for furniture, rfid seal for oil and gas, rfid seal for pallet jacks