Our RFID seals for containers combine a locking wire, ABS housing, serialized UHF identity and electronic tamper detection. The 133 × 38 × 16 mm hanging seal supports container registration at loading points, ports, logistics gates and controlled receiving locations.
RFID Container Seal Specifications
The listed CAB1 or VBL7-NC configuration communicates through ISO 18000-6C Gen2V2 and provides separate memory areas for tag identity, EPC data and project-defined records.
| Specification | Listed Configuration | Container Project Requirement |
|---|---|---|
| Tag dimensions | 133 × 38 × 16 mm | Check clearance around the container locking bars. |
| Antenna dimensions | 93 × 26 mm aluminum antenna | Keep the housing clear of obstructing metal parts. |
| Net weight | 50 g without wire | Add the selected wire to the installed weight. |
| Chip | CAB1 or VBL7-NC | Confirm chip and status commands with the integrator. |
| Protocol | ISO 18000-6C Gen2V2 | Use compatible UHF readers and software. |
| TID or UID | 112 bits | Map the identity to the container and shipment. |
| EPC or Block memory | 192 bits | Define the EPC numbering structure before production. |
| User File_0 | 512 bits | Allocate compact project data where required. |
| Reserved memory | 112 bits | Specify applicable access-control settings. |
| Operating frequency | 860–960 MHz | Confirm every country and port in the route. |
| Housing | ABS plastic | Validate actual transport and storage exposure. |
| Reference read range | Up to 11 m in open-air conditions | Test the completed reader lane with containers. |
| Installation | Hanging style with locking wire | Confirm wire length, diameter and sealing route. |
| Characteristic | Electronic tamper detection | Define the response for each detected condition. |
Connect the Seal to the Container Record
A reliable deployment creates the digital relationship before dispatch and verifies it again at every controlled handover.
Identify the Container
Capture the container number, shipment reference, route and responsible loading location.
Assign the RFID Seal
Link the EPC, chip identity and visible seal number with the correct container record.
Lock and Confirm
Route the wire through the approved locking point and verify the electronic condition.
Release for Dispatch
Approve departure only after the container, seal identity and expected condition match.
Container Handover Points
Each reader event should answer a defined operational question instead of creating an isolated scan record.
Was the Correct Seal Applied?
Verify the container number, visible serial, EPC and locking event before the unit leaves the shipper.
Does the Arrival Match the Booking?
Compare the captured seal identity with the container and transport record expected at the gate.
Was Opening Authorized?
Record the inspector, time and reason before opening, then assign the replacement seal if required.
Is the Seal Condition Expected?
Check the electronic result during changes between truck, rail, warehouse or port custody.
Did the Assigned Seal Arrive?
Match the incoming tag with the original dispatch record before accepting the container.
Can the Container Be Released?
Complete the final identity and condition check before authorized wire removal and unloading.
Define the Gate Reading Environment
Container steel, adjacent lanes, stacked units and varying seal orientation affect UHF performance. Site acceptance should reproduce the actual operating environment.
| Site Variable | Information to Confirm | Test Result Required |
|---|---|---|
| Lane geometry | Lane width, container position and reader distance | Coverage across the approved vehicle path |
| Reader antennas | Quantity, height, angle and polarization | Stable capture at expected seal orientations |
| Container speed | Minimum, typical and maximum gate speed | Required identity and condition captured in motion |
| Nearby metal | Doors, locking bars, barriers and adjacent containers | No unacceptable blind areas in the reading zone |
| Multiple tags | Other UHF tags present on trucks and containers | Software selects the intended seal record |
| Regional frequency | Countries and local UHF reader settings | Approved configuration for each deployment site |
Handle Seal Exceptions Consistently
| Observed Event | System Comparison | Operational Action | Record to Retain |
|---|---|---|---|
| Expected seal and condition | Identity matches the active container record | Continue the approved movement | Time, reader and location |
| Unexpected seal identity | EPC does not match the assigned shipment | Hold the container for record verification | Detected and expected identities |
| Changed seal condition | No authorized opening event is recorded | Route the container to inspection | Condition, time and inspection result |
| Unreadable RFID seal | No reliable electronic response is available | Use controlled close-range and visual checks | Reader attempt and visible serial |
| Authorized inspection opening | Opening request matches an approved event | Inspect and issue a replacement seal | Old seal, new seal and authorizing party |
Printing, Serialization and Encoding
We can coordinate the visible seal information and RFID data so operators, readers and the container-management system reference the same assigned unit.
Visible Seal Data
- Sequential container seal number
- Barcode or QR code
- Company logo and operating text
- Monochrome or approved color printing
- Laser-marked information where specified
RFID Data
- Project-defined EPC structure
- TID or UID collection
- User File_0 allocation
- Required memory access settings
- Encoding and read-back verification
Data Reconciliation
- EPC-to-printed-number matching
- Container and shipment association
- Duplicate-identifier checking
- Production sequence management
- Finished encoding output file
Container Deployment Qualification
Approve the seal on real container doors and through the intended reader infrastructure before releasing a volume order.
Physical Qualification
- Locking-bar clearance and wire route
- Wire diameter and required length
- Housing movement during transport
- Authorized cutting or opening method
- Printing and serial visibility
System Qualification
- Reader compatibility and command support
- Locked-seal reading at every gate
- Tamper-condition recognition
- EPC and container-record matching
- Exception and replacement-seal workflow
Information Needed for Configuration
Container and Route
- Container type and locking hardware
- Photographs of the sealing position
- Transport modes and transfer points
- Countries and ports on the route
Reader Infrastructure
- Reader and antenna models
- Lane width and vehicle speed
- Required reading distance
- Software and status commands
Customization and Order
- Wire diameter and length
- Artwork and visible numbering
- EPC and encoding rules
- Quantity and delivery schedule
Related Container Security Products
Compare mechanical structure, read range, frequency, memory and tamper-condition requirements before selecting another RFID seal.
RFID Container Seal Questions
The listed reference is up to 11 m in unobstructed open-air conditions. Actual performance depends on reader power, antenna layout, seal orientation, container metal, vehicle speed and applicable radio limits.
The passive UHF seal is detected when it enters the coverage of a compatible reader. Continuous location tracking requires separate reader infrastructure, network connectivity and management software.
The listed CAB1 or VBL7-NC configuration supports electronic tamper detection. Compatible readers and software must retrieve the condition and compare it with the authorized shipment history.
The product operates within the 860–960 MHz UHF range, but regional regulations and reader frequencies differ. Provide all countries and ports so the appropriate configuration can be reviewed.
The listed chip provides 192-bit EPC memory and 512-bit User File_0 memory. Compact identifiers or project data may be encoded, while detailed and frequently updated shipping records are generally maintained in the connected database.
Yes. We can review sequential printing, barcode or QR-code data, EPC encoding and the required reconciliation file after the numbering structure is confirmed.
Please provide the container locking-point photographs, wire requirements, transport route, frequency region, reader models, encoding rules, artwork, quantity and delivery schedule.
Configure RFID Seals for Your Container Route
Send us the container hardware, wire requirements, operating countries, reader setup, status workflow, artwork, encoding rules and quantity for configuration review and pricing.
Request a Container Seal ReviewHot Tags: rfid seals for containers, China rfid seals for containers manufacturers, suppliers, factory, rfid seal for alcohol, rfid seal for construction, rfid seal for conveyor belts, rfid seal for document, rfid seal for ip cameras, rfid seal for scanners