RFID E Seals Tag

RFID E Seals Tag

Four-state electronic seal and high-security anti-theft design.
UHF RFID cable seals are ideal for container management and theft prevention.
The tags are equipped with advanced RFID chips and durable, tamper-resistant firmware.
Any attempt to damage or remove the seal will leave visible evidence of tampering.
Send Inquiry
Description

Our RFID e-seals tag combines a single-use locking mechanism, galvanized steel cable, battery-assisted UHF reading and electronic seal detection. The 421 × 50 × 19 mm IP66 construction is suited to containers, trailers, warehouse assets and other compatible logistics closures.

RFID E-Seals Tag Specifications

The listed 902–928 MHz configuration uses a CAB1 or VBL7-NC chip with ISO 18000-6C Gen2V2 communication and separate identity, EPC, user and reserved memory areas.

Specification Listed Configuration Project Selection
Tag dimensions 421 × 50 × 19 mm Check clearance at the selected locking point.
Antenna dimensions 98 × 36.7 mm Approve housing position and orientation.
Chip CAB1 or VBL7-NC Select according to detection requirements.
Protocol ISO 18000-6C Gen2V2 Confirm reader and firmware compatibility.
TID or UID 112 bits Define its relationship with the asset record.
EPC or Block memory 192 bits Provide the required identifier format.
User File_0 512 bits Define data fields and permissions.
Reserved memory 112 bits Confirm access-control ownership.
Operating frequency 902–928 MHz Verify the frequency at every deployment site.
Housing and cable ABS housing and galvanized steel cable Specify cable size and exposure conditions.
Reference read range Up to 15 m on metal Test with the final reader infrastructure.
Installation Locking style Approve the locking and removal sequence.
Colors Yellow, red or green; customization available Define color allocation and print contrast.
Battery Embedded 165 mAh coin battery Control storage and activation dates.
Listed endurance Up to 12 months after locking Include route and storage duration.
Protection IP66 and suitable for on-metal use Qualify the applied assembly.
Detection Tamper-detection sensor Define commands and exception actions.

Select the E-Seal by Operating Task

The same seal body may serve different logistics processes, but cable fit, reader coverage, data fields and exception rules must be configured for each task.

Container Transportation

Link the RFID identity with the container, booking and shipment before final door closure.

Truck and Trailer Doors

Verify the assigned seal at fleet dispatch, route checkpoints and receiving gates.

Port and Terminal Gates

Use fixed-reader lanes to compare arriving seals with expected movement records.

Warehouse Security

Protect compatible cages, cabinets or high-value inventory areas with controlled access records.

Cross-Border Logistics

Capture identity and seal events at approved customs, transfer and bonded-storage locations.

High-Value Asset Control

Associate the seal with equipment or cargo requiring documented custody and opening authorization.

Choose the Required Detection Workflow

State terminology and command behavior must be approved for the selected chip. The software should compare the detected result with the expected stage of operation.

Operational Stage Expected Result System Check Required Action
Seal inventory Available for assignment EPC, TID and visible serial are registered Release only approved stock
Before locking Pre-lock condition Seal matches the correct cargo or asset Correct mismatches before closure
After locking Secured condition Reader confirms the assigned seal result Save as the dispatch baseline
Transit checkpoint No unauthorized change Identity and condition match the route record Continue or route to inspection
Authorized opening Approved removal event Operator and reason are authorized Close the old record and replace the seal
Unexpected opening Tamper exception No approved event explains the change Hold and investigate the protected item

Implement the Seal in Four Steps

1

Register

Import the RFID identity, printed serial and production batch into the issue system.

2

Assign

Connect the seal with the container, vehicle, asset, cargo and route record.

3

Lock

Install the cable through approved hardware and capture the initial electronic result.

4

Verify

Compare the identity and condition at each defined checkpoint before release.

Reader Integration Requirements

Reader Hardware

  • 902–928 MHz operating support
  • Gen2V2 command compatibility
  • Fixed or handheld reader model
  • Antenna gain and polarization
  • Reader firmware version

Site Configuration

  • Lane width and vehicle speed
  • Seal position and orientation
  • Nearby metal and tagged assets
  • Required reading distance
  • Inspection-station layout

Software Integration

  • EPC and TID capture
  • Detection-result interpretation
  • Asset and shipment matching
  • User permissions
  • Exception and audit records

Validate the On-Metal Reading Zone

Test Variable Test Setup Acceptance Result
Seal orientation Test every approved installation direction Required data is captured consistently
Reader distance Measure across the complete operating zone Project range is met with margin
Metal environment Use the final container, vehicle or equipment No unacceptable blind positions remain
Movement speed Run assets through the gate at operating speed Identity and detection data are captured
Adjacent tags Include nearby tagged cargo and vehicles Software selects the intended e-seal
Weather conditions Repeat checks under expected site exposure Required operation remains acceptable

Battery Inventory and Route Planning

1

Receive by Batch

Retain production, incoming inspection and storage records for each batch.

2

Rotate Stock

Issue approved inventory according to its production and receipt sequence.

3

Record Locking

Capture the date when the seal begins its battery-supported service period.

4

Allow for Delays

Include transport, terminal, customs and warehouse delays in service time.

Production and Order Verification

Verification Area Order Check Output
Housing and cable Dimensions, color, assembly and locking Approved physical configuration
RFID identity Chip response, TID and EPC Readable electronic identity
Memory encoding EPC, user fields and access settings Verified encoded records
Detection function Approved locking and opening sequence Defined reader result
Visible printing Serial, barcode, logo and text Approved appearance and readability
Data matching Printed data against RFID data Reconciliation or encoding file
Packaging Quantity, batch and issue sequence Traceable shipment arrangement

Customization for OEM and Integration Projects

Physical Options

  • Steel-cable dimensions
  • Yellow, red or green housing
  • Custom color identification
  • Locking-point requirements
  • Project packaging format

Visible Identification

  • Company logo and operating text
  • Sequential serial numbers
  • Barcode or QR code
  • Asset or route information
  • Variable-data printing

RFID Configuration

  • EPC numbering structure
  • TID and serial association
  • User-memory encoding
  • Access-setting requirements
  • Finished data output

Information Needed for Configuration

Physical Application

  • Container, vehicle or asset type
  • Locking-point photographs
  • Cable diameter and length
  • Outdoor and handling conditions

System Requirements

  • Deployment country
  • Reader and antenna models
  • Required reading distance
  • Detection and software workflow

Order Requirements

  • Artwork and serial rules
  • EPC and memory specification
  • Data-output format
  • Quantity and delivery schedule

Related RFID Electronic Seals

Compare dimensions, frequency, read range, battery endurance, detection functions and locking hardware before selecting another e-seal.

RFID E-Seals Tag Questions

Can the RFID e-seal be reused after locking? +

The listed product is intended for one locking cycle. After authorized opening or cable removal, close its record and assign a new seal if secured custody continues.

Does a standard EPC reader support the detection sensor? +

Basic EPC inventory may not retrieve all detection functions. Confirm CAB1 or VBL7-NC support, Gen2V2 commands, reader firmware and integration software.

Is the 15-meter on-metal reading distance guaranteed? +

No. Up to 15 m is a reader-dependent reference. Reader power, antenna placement, metal structures, seal orientation, interference and movement speed affect the actual distance.

Can this 902–928 MHz tag be used in every country? +

No. Regional UHF regulations differ. Provide every country where the tag will be read so the frequency and reader configuration can be reviewed.

How much user memory does the tag provide? +

The listed configuration provides 512 bits of User File_0 memory, together with 112-bit TID or UID, 192-bit EPC or Block memory and 112-bit reserved memory.

How long can the embedded battery operate? +

The listed 165 mAh battery supports up to 12 months after locking. Storage, temperature, reader activity, detection behavior and route duration can affect achieved endurance.

What information is required for a quotation? +

Please provide the locking-point photographs, cable requirements, deployment countries, route duration, reader setup, detection workflow, artwork, RFID data rules, quantity and delivery schedule.

Configure the E-Seal for Your Logistics Operation

Send us the locking hardware, cable dimensions, operating region, route duration, reader infrastructure, detection workflow, artwork, encoding rules and quantity for review.

Request an RFID E-Seal Tag Review

Hot Tags: rfid e seals tag, China rfid e seals tag manufacturers, suppliers, factory, RFID Cable Seal, rfid seal for artificial intelligence software, rfid seal for demultiplexers, rfid seal for energy management, rfid seal for file, rfid seal for nuclear power

Send Inquiry

(0/10)

clearall