Our RFID seal tag for containers combines a galvanized steel cable, long-range UHF identification and electronic condition sensing in an IP66 ABS housing. It can link a sealed container with its booking, container number, shipment record and authorized handover events.
RFID Container Seal Specifications
Confirm the physical fit, regional frequency, memory plan, reader infrastructure and required sensor workflow before approving the configuration.
| Specification | Listed Configuration | Container Project Requirement |
|---|---|---|
| Seal dimensions | 341 × 50 × 19 mm | Check the door-gear clearance and cable route. |
| Chip | CAB1/VBL7-NC | Confirm reader and middleware compatibility. |
| Protocol | ISO 18000-6C Gen2 V2 | Approve the communication and data workflow. |
| TID/UID | 112 bits | Map the device identity during commissioning. |
| EPC memory | 192 bits | Define the primary seal identity structure. |
| User memory | 512-bit User File_0 | Approve fields, offsets and update rights. |
| Reserved memory | 112 bits | Control passwords and authorized access. |
| Operating frequency | 865–868 MHz | Confirm ETSI-region deployment. |
| Reference read range | Up to 25 m, reader dependent | Validate the terminal or depot reading zone. |
| Housing and cable | ABS housing and galvanized steel cable | Confirm the application point and cable length. |
| Wire diameter | 4 mm, customizable | Specify the required mechanical interface. |
| Protection and placement | IP66; on-metal use supported | Test on the actual container door assembly. |
| Sensing | Seal detection and temperature sensing | Define the reader commands and exception rules. |
| Battery | Embedded 165 mAh coin cell | Confirm activation, storage and voyage duration. |
Bind the Seal to the Container Before Release
The container number and RFID seal identity should be reconciled before the unit enters the transport network.
Identify the Container
Capture the container number, size and type, booking and planned shipment reference.
Assign the RFID Seal
Link the EPC, TID and visible seal number with the selected container record.
Complete the Closure
Route and lock the cable at the approved door point using the documented procedure.
Verify Before Release
Read the installed seal and confirm that all physical and electronic identities agree.
Build a Container Custody Record
| Custody Point | RFID Check | Supporting Record | Exception Action |
|---|---|---|---|
| Stuffing location | Read the seal assigned to the container | Container, booking, cargo and operator | Correct any identity mismatch before release |
| Depot exit | Confirm the expected EPC and seal condition | Vehicle, driver, time and facility | Hold an unknown or unexpected result |
| Terminal gate-in | Compare the read with the advance record | Terminal, lane and gate event | Route the unit to controlled inspection |
| Transshipment handover | Verify the continuing seal-to-container link | Facility, carrier and transfer time | Document any authorized seal replacement |
| Destination release | Retrieve identity and available condition data | Receiver, release and inspection result | Prevent automatic opening approval |
| Authorized opening | Close the active seal-use record | Opening party, time and final disposition | Retain evidence under the buyer's procedure |
Separate Container, Seal and Shipment Identities
Keeping each identifier in its correct role prevents a reusable logistics reference from being confused with a single seal event.
Container Identity
- Container number
- Size and equipment type
- Owner or operator reference
- Container master record
Seal Identity
- Electronic Product Code
- Chip TID or UID
- Visible serial or barcode
- Seal commissioning record
Shipment Identity
- Booking or transport reference
- Origin and destination
- Cargo and responsible parties
- Expected custody events
Engineer Terminal and Depot Reading Zones
Lane Definition
Set the antenna position, reader power and vehicle stopping point around the actual gate width and traffic pattern.
Read Association
Associate each read with the correct lane and container while filtering seals on adjacent vehicles or stored inventory.
Manual Resolution
Provide a handheld verification process for missed reads, conflicting identities and containers routed to inspection.
Allocate Tag Memory and Backend Data
| Data Element | Recommended Location | Reason | Ownership Decision |
|---|---|---|---|
| Primary seal identity | EPC memory | Supports routine UHF identification | Define the unique numbering authority |
| Device identity | TID/UID | Supports commissioning and reconciliation | Define when TID capture is mandatory |
| Compact operational fields | 512-bit user file | Makes selected data available on the tag | Set format and update permissions |
| Container and booking details | Backend database | Detailed records can change during transit | Assign the authoritative system |
| Custody history | Backend event log | Preserves time, reader and facility context | Define retention and access rules |
Validate the Seal on the Container Door
Fit
Check the cable diameter, length, routing, bend radius and housing clearance.
Read
Measure performance across planned lanes, readers and container orientations.
Detect
Exercise the approved seal sequence and verify each returned condition.
Reconcile
Compare the EPC, printed number, container number and shipment record.
Printing, Encoding and Order Preparation
Visible Identification
- Human-readable seal number
- Barcode or QR code
- Customer logo and text
- Required housing color
Electronic Data
- EPC numbering structure
- User-memory data map
- Password and access rules
- Post-encoding verification
Project Information
- Container door photographs
- Cable diameter and length
- Reader and software details
- Quantity and destination country
Related RFID Container Security Products
Compare frequency, read range, sensing, cable construction and system requirements across related electronic and passive container seals.
RFID Seals for Containers Questions
No. The container number identifies the equipment, while the RFID seal has its own electronic and visible identities. The project database should bind them for the specific shipment.
No. The stated distance is a reader-dependent maximum. Actual results depend on antennas, power, orientation, container geometry, lane layout, interference and regional operating limits.
Not without confirming measurement range, accuracy, sampling behavior, reader interaction and validation requirements. The temperature function should be evaluated against the buyer's cargo-monitoring standard.
Treat it as a reference maximum after locking. Confirm storage time, activation method, reader interaction, ambient temperature and expected voyage duration for the configured project.
Please provide the container and door type, cable dimensions, operating regions, voyage duration, readers, required seal states, temperature workflow, memory map, artwork, encoding data and quantity.
Configure the Seal Around Your Container Route
Send us the container door details, cable requirement, operating region, route duration, reader layout, seal-state workflow, memory map, artwork, encoding data and quantity for review and pricing.
Request a Container Seal ReviewHot Tags: rfid seals tag for container, China rfid seals tag for container manufacturers, suppliers, factory, rfid seal for confectionery, rfid seal for conveyor belts, rfid seal for database management systems, rfid seal for packing machines, rfid seal for sorting systems, rfid seal for voip phones