RFID Tamper Evident Cable Seal

RFID Tamper Evident Cable Seal

Disposable plastic cable seal – secure once locked
Waterproof (IP66) and on-metal usable design
Customized barcode,text,and encoding services
Rapid sample lead time (2–3 days)
Ideal for logistics, container sealing,and industrial tracking
Send Inquiry
Description

Our RFID tamper evident cable seal combines a disposable cable-tie closure with UHF identification in a PC housing. Available configurations support tamper detection and temperature sensing for logistics, reusable transport equipment and industrial inspection projects.

RFID Tamper Evident Cable Seal Specifications

We offer UP240130A / UP240132A configurations. Select the chip and sensing functions together with the reader interface and installation requirements.

Parameter Listed Configuration
Part numbers UP240130A / UP240132A
Overall dimensions 270 × 33.5 × 5.8 mm
Chip options CAB1 / VBL7-NC; confirm the chip-to-model selection
RFID protocol ISO 18000-6C, EPC Gen2 V2
Operating frequency 860–960 MHz; reader settings must suit the country of use
TID / UID 112 bits in the published configuration
EPC memory 192 bits in the published configuration
User memory 512 bits; confirm availability with the selected chip
Reserved memory 112 bits in the published configuration
Housing material PC, polycarbonate
Installation Hanging, cable-tie style; disposable locking closure
Reference reading distance Up to 5 m, dependent on reader and installation
Ingress protection IP66
Metal compatibility Metal-compatible design; validate the final mounting position
Sensing functions Tamper detection and temperature sensing; confirm the functions supplied with each model
Colors Green, red, white or customized
Personalization Barcode printing, laser engraving, embossing and RFID encoding

Choose the Seal Position Around the Opening

Fit the tie through fixed and moving parts so opening the protected access point requires disturbing the seal. The 270 mm overall dimension is not the available loop circumference.

Transport Boxes and Totes

Route the tie through aligned lid and body eyelets. Check that the lid cannot be lifted far enough to access the contents while the seal remains intact.

Equipment Access Panels

Use compatible panel and frame attachment points. Position the RFID housing where an inspector can read it without opening the protected panel.

Metal Cages and Fixtures

Evaluate the metal-compatible design on the actual cage, latch or bracket. Check reader approach, nearby metal and clearance around the locking head.

Read Identity, Tamper Status and Temperature

Define the information required from each inspection before selecting the sensing configuration. EPC inventory and sensor access may use different reader commands.

Information Project Use Integration Requirement
RFID identity Associate the seal with a shipment, box or equipment record. Agree the EPC format and any required TID capture.
Tamper status Check the reported seal condition during inspection. Confirm the trigger, status field and behavior after cutting or attempted reconnection.
Temperature Obtain a temperature reading from the selected sensor configuration. Confirm measurement range, accuracy, read command and sensor location.
Inspection history Store the observed result against a known asset or shipment. The connected system supplies timestamps, checkpoint information and record storage.

Sample Tests Before Deployment

Test the complete RFID tamper evident cable seal on the intended closure, using the production reader and software.

Test Procedure Record
Closure fit Thread and lock the tie through the actual attachment points. Usable loop size, engagement and access to the protected opening.
Intact baseline Read the applied seal before disturbing it. EPC, available TID, reported seal state and reader settings.
Controlled cutting Cut the tie on a dedicated test sample and repeat the read. Physical damage, tag readability and the returned tamper status.
State persistence Remove the sample from the reader field and inspect it again. Whether the detected state persists under the agreed test conditions.
Temperature response Compare the selected sensor with a suitable reference at agreed test points. Reading difference, stabilization time and measurement conditions.
Installed read zone Read from normal inspection positions with surrounding materials in place. Successful read distance, angle and sensor-access performance.

Printing and RFID Configuration

Visible Identification

  • Mono or color barcode printing
  • Company text and serial numbers
  • Laser engraving or embossing
  • Green, red, white or custom color

Electronic Data

  • Customer-defined EPC format
  • Approved user-memory content
  • Visible-to-electronic identifier mapping
  • Reader and sensor-command requirements

Order Specification

  • Selected part number and chip
  • Required sensing functions
  • Artwork and encoding approval
  • Quantity, packaging and destination

Select the Right RFID Seal Construction

Choose the locking structure to suit the opening and mechanical security requirement. Select readers separately for the required identification and sensor functions.

RFID Tamper Evident Cable Seal Questions

Is this a steel cable seal or a plastic tie seal? +

This model is a disposable plastic cable-tie-style seal with a PC housing. It should not be specified as a steel wire or high-security bolt seal.

Do both part numbers include the same sensing functions? +

Confirm the selected part number, chip and required functions with us. The product family lists tamper detection and temperature sensing, but the exact function and memory allocation must be agreed for the supplied configuration.

Does tamper detection mean the tag stops responding? +

Not necessarily. A status-reporting seal and a tag that becomes unreadable are different designs. Confirm the selected model's response after cutting, including whether its identity remains readable and how the tamper result is retrieved.

Can it record the exact time of an opening? +

The listed specification does not establish an autonomous clock or opening-event logger. Your system can timestamp an inspection, but that timestamp is not necessarily the time when the seal was disturbed.

Does temperature sensing include a complete transport history? +

Temperature sensing alone does not establish continuous logging. Specify whether you need a reading at inspection, recorded samples or an excursion history so we can review the appropriate configuration.

Will the seal read at five meters on metal? +

Five meters is the listed maximum reference distance, not a guaranteed installed range. Test the metal-compatible design on your hardware. Sensor commands may also have a different operating range from ordinary EPC inventory.

Can it replace a certified high-security container seal? +

This plastic cable-tie seal should not be treated as a certified high-security container seal without model-specific evidence. Where a shipment requires a particular mechanical classification, select a seal with matching documentation.

What information do you need to recommend a configuration? +

Send us the sealing-point dimensions and photographs, surrounding materials, desired tamper response, temperature requirements, reader model, country of use, encoding format, artwork and quantity.

Specify the Closure and Sensing Requirements

Share your sealing-point photos, required tamper response, temperature measurement needs and reader setup. We will review the model, marking and encoding requirements for your order.

Request a Cable Seal Configuration

Hot Tags: rfid tamper evident cable seal, China rfid tamper evident cable seal manufacturers, suppliers, factory, rfid seal for application software, rfid seal for customer relationship management systems, rfid seal for door locks, rfid seal for financial management systems, rfid seal for hazardous materials, rfid seal for project management systems

Send Inquiry

(0/10)

clearall