Induction Security Seal
video
Induction Security Seal

Induction Security Seal

Any attempt to remove the tag will cause the tag to be damaged and leave obvious traces.
Tags can be read using NFC-enabled devices without the need for specialized equipment.
NFC technology has good compatibility and can be easily expanded to management systems.
NFC tags have low operating costs and do not require complex equipment and network facilities.
Send Inquiry
Description

Our induction security seal uses an ISO 15693 high-frequency module for deliberate close-range verification at a protected opening. Its compact construction is suited to workflows where an authorized operator presents a compatible reader before access, inspection or seal replacement.

Induction Security Seal Specifications

The short reading distance supports an intentional inspection action and reduces unintended reads from other secured items nearby.

Specification Listed Configuration Project Requirement
Module dimensions 19.5 × 20 × 0.45 mm Confirm the available installation area.
Chip FM13HS01-P Verify reader and command compatibility.
Protocol ISO 15693 Confirm support in every reading device.
User memory 1024 bits Approve the data map and write permissions.
Operating frequency 13.0–14.5 MHz Use an HF reader configured for the chip.
Reference read range Up to 4.4 cm in free air Test through the final housing and surface.
Surface construction Protective ink overlay Confirm abrasion and handling requirements.
Installation Tie, tighten, insert or locking style Define the complete mechanical assembly.
Color Yellow or customized Approve visual identification rules.
Security function Tamper-proof and detection function Validate state behavior after disturbance.

Use Close-Range Reading as an Inspection Step

1

Select

Retrieve the expected asset, compartment or shipment record before approaching the seal.

2

Present

Place the approved ISO 15693 reader at the documented tap or scan position.

3

Compare

Check the returned identity and supported condition against the expected record.

4

Authorize

Permit access, hold the item or escalate the exception under the project rules.

Define Access Decisions Before Deployment

Reader Result Record Comparison Operator Response Access Outcome
Expected identity Seal matches the selected asset record Continue with condition and visual checks Pending complete authorization
Unknown identity No approved record exists Hold the secured item Access denied or escalated
Wrong asset Known seal belongs to another record Stop the opening procedure Identity mismatch
Unexpected condition Returned result differs from expectation Perform controlled inspection Security exception
No response Identity cannot be retrieved Check placement, reader and visible damage Do not assume an intact seal

Choose the Protected Access Point

Equipment Panel

Position the seal across the controlled cover or closure without placing the HF module directly against metal.

Storage Box or Case

Bridge the actual opening route and keep the approved reader position accessible to inspectors.

Cabinet or Meter Point

Confirm surface construction, curvature, clearance and whether nearby wiring affects the installed read.

Verify Reader and Phone Compatibility

Device Type Compatibility Check Required Test Deployment Decision
Industrial ISO 15693 reader Protocol and chip command support Read identity, memory and required condition Approve the reader and firmware version
Handheld HF terminal Antenna position and application support Repeat reads through the installed surface Document the scan location and angle
NFC-enabled smartphone ISO 15693 support varies by device Test every approved phone and operating system Do not assume universal phone support
Desktop encoder Memory access and write commands Write and read back the approved data map Set encoding and verification rules

Plan the 1024-Bit User Memory

On-Tag Fields

  • Compact asset identifier
  • Site or equipment code
  • Approved fixed project fields
  • Required condition information

Backend Fields

  • Responsible employee
  • Access and inspection history
  • Location and service details
  • Exception photographs and decisions

Data Governance

  • Memory map and field length
  • Write and update permissions
  • Reader application behavior
  • Record-retention requirements

Test Removal and Disturbance Results

1

Install

Apply the completed seal construction to the actual protected access point.

2

Read

Confirm the intended identity, memory and condition before disturbance.

3

Disturb

Perform the approved peel, cut, opening or removal test on the assembly.

4

Compare

Inspect visible damage and verify the electronic result after disturbance.

Information Needed for Configuration

Physical Security Requirements

  • Protected access point and photographs
  • Surface material and nearby metal
  • Opening or removal direction
  • Available installation area
  • Expected handling environment

Data and Reading Requirements

  • Reader or phone models
  • Required identity and condition data
  • User-memory field structure
  • Color, printing and encoding needs
  • Quantity and destination country

Related HF and RFID Security Seals

Compare protocol, read distance, installation structure and condition-detection requirements before selecting another seal.

Induction Security Seal Questions

Can every NFC phone read this ISO 15693 seal? +

No. NFC phone hardware, operating systems and application support vary. Test every intended phone model with the FM13HS01-P chip and required data functions before deployment.

Will the seal always read from 4.4 centimetres? +

No. It is a free-air reference maximum. Reader antenna size, alignment, installation layers, nearby metal, curvature and interference can reduce the usable distance.

Does the seal continuously monitor or transmit its location? +

A location event is created only when a compatible reader checks the seal at a known place.

Can the module be installed directly on metal? +

Direct metal placement may interfere with a standard HF antenna. Provide the surface construction so spacing, installation position and the completed seal assembly can be tested.

Can all inspection history be stored in 1024 bits? +

The memory can hold selected compact fields, but detailed access times, operators, locations, photographs and exception records should normally remain in the backend system.

How should tamper detection be validated? +

Install the completed seal on the actual surface, record its initial result, reproduce the planned removal or opening action, then compare visible damage and the electronic response.

What information is required for a quotation? +

Please provide the protected access point, surface material, available area, removal method, reader or phone models, memory map, required condition data, color, printing, quantity and destination.

Configure the Seal Around the Inspection Point

Send us the protected access point, surface structure, available area, removal method, reader models, required condition data, memory map, color, printing and quantity for review and pricing.

Request an Induction Seal Review

Hot Tags: induction security seal, China induction security seal manufacturers, suppliers, factory, rfid seal for bricks, rfid seal for chemicals, rfid seal for conveyor belts, rfid seal for microprocessors, rfid seal for payroll software, rfid seal for perishable goods

Send Inquiry

(0/10)

clearall