Our induction security seal uses an ISO 15693 high-frequency module for deliberate close-range verification at a protected opening. Its compact construction is suited to workflows where an authorized operator presents a compatible reader before access, inspection or seal replacement.
Induction Security Seal Specifications
The short reading distance supports an intentional inspection action and reduces unintended reads from other secured items nearby.
| Specification | Listed Configuration | Project Requirement |
|---|---|---|
| Module dimensions | 19.5 × 20 × 0.45 mm | Confirm the available installation area. |
| Chip | FM13HS01-P | Verify reader and command compatibility. |
| Protocol | ISO 15693 | Confirm support in every reading device. |
| User memory | 1024 bits | Approve the data map and write permissions. |
| Operating frequency | 13.0–14.5 MHz | Use an HF reader configured for the chip. |
| Reference read range | Up to 4.4 cm in free air | Test through the final housing and surface. |
| Surface construction | Protective ink overlay | Confirm abrasion and handling requirements. |
| Installation | Tie, tighten, insert or locking style | Define the complete mechanical assembly. |
| Color | Yellow or customized | Approve visual identification rules. |
| Security function | Tamper-proof and detection function | Validate state behavior after disturbance. |
Use Close-Range Reading as an Inspection Step
Select
Retrieve the expected asset, compartment or shipment record before approaching the seal.
Present
Place the approved ISO 15693 reader at the documented tap or scan position.
Compare
Check the returned identity and supported condition against the expected record.
Authorize
Permit access, hold the item or escalate the exception under the project rules.
Define Access Decisions Before Deployment
| Reader Result | Record Comparison | Operator Response | Access Outcome |
|---|---|---|---|
| Expected identity | Seal matches the selected asset record | Continue with condition and visual checks | Pending complete authorization |
| Unknown identity | No approved record exists | Hold the secured item | Access denied or escalated |
| Wrong asset | Known seal belongs to another record | Stop the opening procedure | Identity mismatch |
| Unexpected condition | Returned result differs from expectation | Perform controlled inspection | Security exception |
| No response | Identity cannot be retrieved | Check placement, reader and visible damage | Do not assume an intact seal |
Choose the Protected Access Point
Equipment Panel
Position the seal across the controlled cover or closure without placing the HF module directly against metal.
Storage Box or Case
Bridge the actual opening route and keep the approved reader position accessible to inspectors.
Cabinet or Meter Point
Confirm surface construction, curvature, clearance and whether nearby wiring affects the installed read.
Verify Reader and Phone Compatibility
| Device Type | Compatibility Check | Required Test | Deployment Decision |
|---|---|---|---|
| Industrial ISO 15693 reader | Protocol and chip command support | Read identity, memory and required condition | Approve the reader and firmware version |
| Handheld HF terminal | Antenna position and application support | Repeat reads through the installed surface | Document the scan location and angle |
| NFC-enabled smartphone | ISO 15693 support varies by device | Test every approved phone and operating system | Do not assume universal phone support |
| Desktop encoder | Memory access and write commands | Write and read back the approved data map | Set encoding and verification rules |
Plan the 1024-Bit User Memory
On-Tag Fields
- Compact asset identifier
- Site or equipment code
- Approved fixed project fields
- Required condition information
Backend Fields
- Responsible employee
- Access and inspection history
- Location and service details
- Exception photographs and decisions
Data Governance
- Memory map and field length
- Write and update permissions
- Reader application behavior
- Record-retention requirements
Test Removal and Disturbance Results
Install
Apply the completed seal construction to the actual protected access point.
Read
Confirm the intended identity, memory and condition before disturbance.
Disturb
Perform the approved peel, cut, opening or removal test on the assembly.
Compare
Inspect visible damage and verify the electronic result after disturbance.
Information Needed for Configuration
Physical Security Requirements
- Protected access point and photographs
- Surface material and nearby metal
- Opening or removal direction
- Available installation area
- Expected handling environment
Data and Reading Requirements
- Reader or phone models
- Required identity and condition data
- User-memory field structure
- Color, printing and encoding needs
- Quantity and destination country
Related HF and RFID Security Seals
Compare protocol, read distance, installation structure and condition-detection requirements before selecting another seal.
Induction Security Seal Questions
No. NFC phone hardware, operating systems and application support vary. Test every intended phone model with the FM13HS01-P chip and required data functions before deployment.
No. It is a free-air reference maximum. Reader antenna size, alignment, installation layers, nearby metal, curvature and interference can reduce the usable distance.
A location event is created only when a compatible reader checks the seal at a known place.
Direct metal placement may interfere with a standard HF antenna. Provide the surface construction so spacing, installation position and the completed seal assembly can be tested.
The memory can hold selected compact fields, but detailed access times, operators, locations, photographs and exception records should normally remain in the backend system.
Install the completed seal on the actual surface, record its initial result, reproduce the planned removal or opening action, then compare visible damage and the electronic response.
Please provide the protected access point, surface material, available area, removal method, reader or phone models, memory map, required condition data, color, printing, quantity and destination.
Configure the Seal Around the Inspection Point
Send us the protected access point, surface structure, available area, removal method, reader models, required condition data, memory map, color, printing and quantity for review and pricing.
Request an Induction Seal ReviewHot Tags: induction security seal, China induction security seal manufacturers, suppliers, factory, rfid seal for bricks, rfid seal for chemicals, rfid seal for conveyor belts, rfid seal for microprocessors, rfid seal for payroll software, rfid seal for perishable goods