Container RFID Seal Tag

Container RFID Seal Tag

High Security 4 States RFID Wire Seal Tag for Container Management
Secure your containers with a fully tamper-proof RFID seal tag.
Suitable for use on metal surfaces without performance degradation.
12-month battery life from the moment the seal is locked.
Monitor containers and detect tampering instantly with RFID readers.
Send Inquiry
Description

Our container RFID seal tag combines long-range UHF identification, an electronic seal-condition function and temperature sensing in an IP66 cable-seal housing. It is designed for container depots and terminals that need to verify the assigned seal before gate release or authorized opening.

Container RFID Seal Tag Specifications

Confirm the reader, regional frequency, door installation, sensing workflow and battery-use conditions before approving a field configuration.

Specification Listed Configuration Deployment Requirement
Seal dimensions 341 × 50 × 19 mm Check clearance around the door gear.
Antenna dimensions 58 × 37 mm Approve the installed antenna orientation.
Chip CAB1/VBL7-NC Confirm reader and firmware support.
Protocol ISO 18000-6C Gen2 V2 Define identity and condition commands.
TID/UID 112 bits Capture during seal commissioning.
EPC memory 192 bits Allocate the primary seal identifier.
User memory 512-bit User File_0 Approve the data fields and offsets.
Reserved memory 112 bits Control access and password ownership.
Operating frequency 865–868 MHz Confirm ETSI-region operation.
Reference read range Up to 25 m, reader dependent Validate each gate and inspection lane.
Housing and cable ABS housing and galvanized steel cable Specify cable diameter, length and routing.
Protection IP66; on-metal use supported Test on the actual container door.
Sensing Condition and temperature sensing Define accepted and exception results.
Battery Embedded 165 mAh coin cell Confirm activation and service duration.

Commission the Container and Seal as One Record

1

Inspect

Confirm the container number, door condition and approved seal application point.

2

Assign

Bind the EPC, TID and visible seal number to the container and booking record.

3

Lock

Install the cable using the approved route and confirm the expected electronic result.

4

Release

Approve gate departure only after the physical and digital records correspond.

Configure Container Gate Reading Zones

Gate Variable Field Test Acceptance Requirement Adjustment Method
Lane width Move the sealed container through the actual lane Read the intended seal throughout the target zone Change antenna position or beam direction
Container orientation Test relevant door and vehicle positions Document a reliable operating window Add or reposition antennas
Adjacent traffic Place tagged units in neighboring lanes Avoid assigning another seal to the event Reduce power and apply lane filtering
Stopped traffic Queue multiple sealed containers near the reader Associate reads with the correct vehicle Use triggers and transaction timing
Missed read Present difficult orientations and interference Route failure to manual verification Provide a handheld inspection station

Control Authorized Seal Replacement

When inspection or operational requirements force a seal change, the old and new identities must remain connected to the same container movement.

Record the Reason

Document inspection, damage, customs action, operational error or another approved replacement reason.

Close the Old Seal

Capture its identity, available condition, removal time, location and responsible officer.

Issue the New Seal

Link the replacement EPC and visible number to the original container and continuing shipment.

Define the Result Shown to Gate Operators

System Result Data Comparison Operator Action Transaction Status
Expected seal EPC matches the active container record Continue the configured condition check Pending final release rule
Unknown seal No authorized record exists Hold the container for inspection Rejected or quarantined
Wrong container Valid seal is assigned elsewhere Prevent automatic gate release Identity mismatch
Unexpected condition Returned result conflicts with the trip stage Perform controlled physical inspection Exception under review
Unreadable seal No reliable electronic response is obtained Use the manual verification procedure Do not infer a valid result

Validate Identity, Condition and Temperature Separately

Identity Test

  • EPC and TID retrieval
  • Container-record matching
  • Visible serial reconciliation
  • Unknown-tag handling

Condition Test

  • Approved installation sequence
  • Expected state at each stage
  • Removal or opening procedure
  • Exception interpretation

Temperature Test

  • Supported measurement range
  • Reader retrieval method
  • Accuracy and response behavior
  • Acceptance thresholds

Plan Device Data and System Data

Information Recommended Location Reason Required Decision
Seal identity 192-bit EPC Supports routine UHF identification Define unique numbering ownership
Device reference 112-bit TID/UID Supports commissioning reconciliation Define mandatory capture points
Compact operational data 512-bit user file Makes selected fields available on the tag Define offsets and update rights
Container and booking details Backend database Detailed information may change Select the authoritative system
Inspection and replacement history Backend event log Preserves location, time and responsibility Define access and retention rules

Information Needed for Site Qualification

Container and Facility

  • Container door and locking-gear photographs
  • Cable diameter and length requirement
  • Lane widths and vehicle positions
  • Expected storage and voyage duration
  • Operating and environmental conditions

RFID and Software

  • Reader, antenna and PDA models
  • Required condition and temperature data
  • EPC and user-memory structure
  • Gate-release and replacement rules
  • Artwork, encoding data and quantity

Related RFID Container Seals

Compare reading range, condition sensing, memory, regional frequency and mechanical requirements across related container-seal configurations.

Container RFID Seal Tag Questions

Which readers can retrieve the seal condition? +

Confirm firmware, commands, frequency, antenna and returned-data interpretation with the exact equipment before deployment.

Is the maximum 25-metre reading distance guaranteed? +

No. Actual range depends on the reader, antenna, permitted power, seal orientation, container geometry, lane layout, nearby tagged units and radio interference.

Does the seal replace a customs-approved bolt seal? +

Not automatically. Confirm customs, carrier, route and mechanical-security requirements separately. An additional certified bolt seal may still be required for a particular shipment.

Does the tag continuously track the container? +

Location events are created when compatible readers interrogate the seal at known gates or inspection points.

Can its temperature sensor replace a validated logger? +

Not without verifying range, accuracy, sampling behavior, retrieval method and applicable cargo requirements. Evaluate the sensor against the project's required monitoring standard.

How should an authorized replacement seal be recorded? +

Close the old seal record with its condition, location, reason and responsible party, then link the new EPC and visible number to the same container and continuing shipment.

What information is required for a site review? +

Please provide container-door photographs, cable requirements, operating region, lane layout, reader models, required condition and temperature data, memory map, artwork, encoding data and quantity.

Qualify the Container Seal and Gate System Together

Send us the container door, cable requirement, operating region, lane layout, reader models, condition workflow, memory map, artwork, encoding data and quantity for configuration review and pricing.

Request a Container Site Review

Hot Tags: container rfid seal tag, China container rfid seal tag manufacturers, suppliers, factory, RFID Container Seal, rfid seal for coding machines, rfid seal for electronics, rfid seal for power plants, rfid seal for sorting systems, rfid seal for textile