Our container RFID seal tag combines long-range UHF identification, an electronic seal-condition function and temperature sensing in an IP66 cable-seal housing. It is designed for container depots and terminals that need to verify the assigned seal before gate release or authorized opening.
Container RFID Seal Tag Specifications
Confirm the reader, regional frequency, door installation, sensing workflow and battery-use conditions before approving a field configuration.
| Specification | Listed Configuration | Deployment Requirement |
|---|---|---|
| Seal dimensions | 341 × 50 × 19 mm | Check clearance around the door gear. |
| Antenna dimensions | 58 × 37 mm | Approve the installed antenna orientation. |
| Chip | CAB1/VBL7-NC | Confirm reader and firmware support. |
| Protocol | ISO 18000-6C Gen2 V2 | Define identity and condition commands. |
| TID/UID | 112 bits | Capture during seal commissioning. |
| EPC memory | 192 bits | Allocate the primary seal identifier. |
| User memory | 512-bit User File_0 | Approve the data fields and offsets. |
| Reserved memory | 112 bits | Control access and password ownership. |
| Operating frequency | 865–868 MHz | Confirm ETSI-region operation. |
| Reference read range | Up to 25 m, reader dependent | Validate each gate and inspection lane. |
| Housing and cable | ABS housing and galvanized steel cable | Specify cable diameter, length and routing. |
| Protection | IP66; on-metal use supported | Test on the actual container door. |
| Sensing | Condition and temperature sensing | Define accepted and exception results. |
| Battery | Embedded 165 mAh coin cell | Confirm activation and service duration. |
Commission the Container and Seal as One Record
Inspect
Confirm the container number, door condition and approved seal application point.
Assign
Bind the EPC, TID and visible seal number to the container and booking record.
Lock
Install the cable using the approved route and confirm the expected electronic result.
Release
Approve gate departure only after the physical and digital records correspond.
Configure Container Gate Reading Zones
| Gate Variable | Field Test | Acceptance Requirement | Adjustment Method |
|---|---|---|---|
| Lane width | Move the sealed container through the actual lane | Read the intended seal throughout the target zone | Change antenna position or beam direction |
| Container orientation | Test relevant door and vehicle positions | Document a reliable operating window | Add or reposition antennas |
| Adjacent traffic | Place tagged units in neighboring lanes | Avoid assigning another seal to the event | Reduce power and apply lane filtering |
| Stopped traffic | Queue multiple sealed containers near the reader | Associate reads with the correct vehicle | Use triggers and transaction timing |
| Missed read | Present difficult orientations and interference | Route failure to manual verification | Provide a handheld inspection station |
Control Authorized Seal Replacement
When inspection or operational requirements force a seal change, the old and new identities must remain connected to the same container movement.
Record the Reason
Document inspection, damage, customs action, operational error or another approved replacement reason.
Close the Old Seal
Capture its identity, available condition, removal time, location and responsible officer.
Issue the New Seal
Link the replacement EPC and visible number to the original container and continuing shipment.
Define the Result Shown to Gate Operators
| System Result | Data Comparison | Operator Action | Transaction Status |
|---|---|---|---|
| Expected seal | EPC matches the active container record | Continue the configured condition check | Pending final release rule |
| Unknown seal | No authorized record exists | Hold the container for inspection | Rejected or quarantined |
| Wrong container | Valid seal is assigned elsewhere | Prevent automatic gate release | Identity mismatch |
| Unexpected condition | Returned result conflicts with the trip stage | Perform controlled physical inspection | Exception under review |
| Unreadable seal | No reliable electronic response is obtained | Use the manual verification procedure | Do not infer a valid result |
Validate Identity, Condition and Temperature Separately
Identity Test
- EPC and TID retrieval
- Container-record matching
- Visible serial reconciliation
- Unknown-tag handling
Condition Test
- Approved installation sequence
- Expected state at each stage
- Removal or opening procedure
- Exception interpretation
Temperature Test
- Supported measurement range
- Reader retrieval method
- Accuracy and response behavior
- Acceptance thresholds
Plan Device Data and System Data
| Information | Recommended Location | Reason | Required Decision |
|---|---|---|---|
| Seal identity | 192-bit EPC | Supports routine UHF identification | Define unique numbering ownership |
| Device reference | 112-bit TID/UID | Supports commissioning reconciliation | Define mandatory capture points |
| Compact operational data | 512-bit user file | Makes selected fields available on the tag | Define offsets and update rights |
| Container and booking details | Backend database | Detailed information may change | Select the authoritative system |
| Inspection and replacement history | Backend event log | Preserves location, time and responsibility | Define access and retention rules |
Information Needed for Site Qualification
Container and Facility
- Container door and locking-gear photographs
- Cable diameter and length requirement
- Lane widths and vehicle positions
- Expected storage and voyage duration
- Operating and environmental conditions
RFID and Software
- Reader, antenna and PDA models
- Required condition and temperature data
- EPC and user-memory structure
- Gate-release and replacement rules
- Artwork, encoding data and quantity
Related RFID Container Seals
Compare reading range, condition sensing, memory, regional frequency and mechanical requirements across related container-seal configurations.
Container RFID Seal Tag Questions
Confirm firmware, commands, frequency, antenna and returned-data interpretation with the exact equipment before deployment.
No. Actual range depends on the reader, antenna, permitted power, seal orientation, container geometry, lane layout, nearby tagged units and radio interference.
Not automatically. Confirm customs, carrier, route and mechanical-security requirements separately. An additional certified bolt seal may still be required for a particular shipment.
Location events are created when compatible readers interrogate the seal at known gates or inspection points.
Not without verifying range, accuracy, sampling behavior, retrieval method and applicable cargo requirements. Evaluate the sensor against the project's required monitoring standard.
Close the old seal record with its condition, location, reason and responsible party, then link the new EPC and visible number to the same container and continuing shipment.
Please provide container-door photographs, cable requirements, operating region, lane layout, reader models, required condition and temperature data, memory map, artwork, encoding data and quantity.
Qualify the Container Seal and Gate System Together
Send us the container door, cable requirement, operating region, lane layout, reader models, condition workflow, memory map, artwork, encoding data and quantity for configuration review and pricing.
Request a Container Site ReviewHot Tags: container rfid seal tag, China container rfid seal tag manufacturers, suppliers, factory, RFID Container Seal, rfid seal for coding machines, rfid seal for electronics, rfid seal for power plants, rfid seal for sorting systems, rfid seal for textile



















