UHF RFID Seal Sticker

UHF RFID Seal Sticker

Any attempt to remove the label will damage it, ensuring it cannot be reused and effectively preventing counterfeiting and tampering.
Unique structural design allows for direct attachment to metal surfaces, ensuring stable performance.
The built-in G2IL+ chip complies with ISO18000-6C GEN2 protocol and supports secure storage and encryption.
The label is made of white PET, offering excellent wear resistance and printability, making it suitable for long-term use.
The adhesive backing allows for quick and easy attachment to packaging or equipment surfaces.
Send Inquiry
Description

Our UHF RFID seal sticker combines a G2IL+ EPC identity, printable white PET face and adhesive tamper-evident structure in a 139 × 40 mm format. It is designed for meter enclosures and equipment access points where field teams need electronic identification and visible evidence of seal removal.

UHF RFID Seal Sticker Specifications

Confirm the meter or equipment surface, protected seam, destination frequency, field reader and inspection procedure before production approval.

Specification Available Configuration Deployment Requirement
Sticker dimensions 139 × 40 × 0.1 mm Measure the enclosure and seam area
Antenna dimensions 83 × 35 mm Keep the active area at the approved position
Chip G2IL+ Confirm reader and middleware compatibility
Protocol ISO 18000-6C / EPC Gen2 Match the regional UHF system
TID/UID 64 bits Define whether TID is captured at commissioning
EPC memory 128 bits Provide the meter or seal numbering structure
User memory 0 bits Store service records in the backend
Reserve memory 32-bit access and 32-bit kill passwords Define password control and authorization
Operating frequency 860–960 MHz Confirm the destination-country band
Reference read range Up to 300 cm in free air Validate the installed meter environment
Face material Printable white PET Approve print and environmental durability
Installation Adhesive, listed for on-metal use Test the exact metal and surface coating

Choose the Meter Sealing Point

The sticker should bridge a controlled opening without covering the meter display, regulatory markings, terminals or required service information.

Main Meter Cover

Bridge the housing and removable cover so authorized access produces an inspectable change.

Terminal Cover

Protect the selected terminal access point without placing the sticker over unsafe or prohibited areas.

Cabinet Door

Apply across a metal cabinet seam when the protected boundary is larger than the individual meter.

Service Panel

Identify the panel and record authorized opening during maintenance, inspection or component replacement.

Instrument Housing

Seal a calibration or configuration access point after testing the specific enclosure geometry.

Protective Package

Apply to an outer package when direct installation on the equipment is unsuitable for the required workflow.

Commission Stickers Before Field Installation

1

Allocate

Assign a unique EPC according to the utility, region, meter type or project numbering rules.

2

Encode

Write the approved EPC and verify the tag before it is released to the installer.

3

Match

Associate the electronic identity with the printed serial and intended meter or equipment record.

4

Issue

Record which installer, team, service area or work order receives each commissioned sticker.

Build a Field Installation Record

Installation Field Required Information Verification Method Record Purpose
Meter identity Meter number, type and customer or site reference Compare visible data with the work order Prevent installation on the wrong meter
Seal identity EPC, TID when required and printed serial Read and compare the applied sticker Create the meter-to-seal relationship
Location Site, route, cabinet or service area Confirm against the assignment record Support future inspection planning
Seal position Approved access point and orientation Photograph or installation-position code Standardize later inspection
Installer Technician, team and installation date Work-order sign-off Maintain installation accountability
Initial condition Adhesion, visual condition and RFID result Final field scan and inspection Establish the acceptance baseline

Organize Route-Based Meter Inspection

Prepare the Route

Load the expected meter and seal records for the area assigned to the field technician.

Identify the Site

Confirm the location and visible meter identity before interpreting an RFID response.

Read the Seal

Use the approved reader, distance and orientation for the installed enclosure configuration.

Inspect Physically

Check the sticker position, edges, printed serial and opening boundary rather than relying on RFID alone.

Classify the Result

Record the seal as intact, unreadable, damaged, missing, replaced or requiring investigation.

Close the Visit

Save the inspection result, technician, date, supporting evidence and required follow-up action.

Define Responses to Seal Conditions

Observed Condition Possible Interpretation Field Action System Update
Intact and readable Seal matches the expected installation condition Complete the routine inspection Record the successful visit
Intact but unreadable Reader, orientation or tag performance issue Repeat the approved troubleshooting process Do not classify as tampering automatically
Visibly damaged Impact, aging, removal attempt or service activity Inspect the access point and supporting records Open an exception case
Seal missing Removal, replacement or incorrect installation record Verify the meter and investigate the history Do not issue a new seal without authorization
Different EPC present Authorized replacement or record mismatch Check the work order and replacement authorization Reconcile old and new identities
Authorized opening Approved maintenance or meter replacement Close the previous seal record Assign and verify a new sticker

Validate On-Metal Installation

The model is listed for use on metal, but actual performance depends on the enclosure geometry, coating, nearby components and reader orientation.

Metal Type

Test the exact steel, aluminum or other substrate used for the meter or equipment housing.

Surface Coating

Check powder coating, paint, texture, corrosion, cleaning agents and surface contamination.

Housing Geometry

Evaluate curves, raised edges, recessed panels and the transition across the protected seam.

Reader Orientation

Record the approved scanning direction and distance for common field-access conditions.

Nearby Meters

Check whether adjacent tagged meters are captured when technicians intend to inspect one device.

Removal Result

Test the physical and electronic response after peeling, cutting or opening the protected cover.

Printing, Encoding and Field Identification

Visible Printing

  • Utility or operator name
  • Seal and meter reference
  • Barcode or QR code
  • Inspection and warning text

RFID Configuration

  • Customer-defined EPC structure
  • TID and EPC relationship
  • Access-password requirement
  • Kill-password requirement

Production Verification

  • Duplicate EPC checking
  • Print-to-encoding comparison
  • RFID functionality test
  • Finished data-file output

Information Needed for Configuration

Meter and Installation Details

  • Meter or equipment type
  • Metal, coating and surface texture
  • Protected cover or enclosure seam
  • Indoor or outdoor environment
  • Installation and inspection procedure

RFID and Order Details

  • Destination country and UHF band
  • Field reader and antenna models
  • EPC and password requirements
  • Artwork and variable-data file
  • Quantity and delivery destination

Related UHF Security Stickers

Compare surface compatibility, frequency, removal behavior, reader distance and inspection workflow before selecting another seal format.

UHF RFID Seal Sticker Questions

Can this sticker be applied directly to a metal meter? +

The product is listed for on-metal use, but the actual metal, coating, curvature, installation position and reader configuration must be tested together.

Does an unreadable sticker prove that a meter was opened? +

No. An unreadable result can also be caused by reader setup, orientation, interference or damage. Physical inspection and service records are required before classification.

Can the sticker store inspection history? +

The listed G2IL+ configuration has no user memory. Installation, inspection, maintenance and replacement history should be stored in a database linked to the EPC.

Does the sticker report tampering in real time? +

This passive UHF sticker has no battery or independent communication link. It is inspected visually or detected when compatible RFID equipment reads it.

Is the three-meter reading distance guaranteed? +

No. Three meters is a reference free-air result. The metal enclosure, tag position, reader, antenna, power and nearby meters determine the installed range.

How is a sticker replaced after authorized service? +

Close the original seal record, document the work order and removal reason, assign a new EPC, install the replacement and verify the new relationship.

What information is required for a quotation? +

Please provide the meter type, metal and coating, protected seam, operating environment, destination country, reader models, EPC rules, artwork, quantity and delivery destination.

Configure UHF Seal Stickers for Field Inspection

Send us the meter or equipment details, metal surface, protected seam, field environment, destination frequency, reader equipment, EPC format, artwork and quantity for review and pricing.

Request a UHF Seal Sticker Review

Hot Tags: uhf rfid seal sticker, China uhf rfid seal sticker manufacturers, suppliers, factory, rfid seal for cables, rfid seal for composting, rfid seal for fish, rfid seal for insulation materials, rfid seal for intrusion detection systems, rfid seal for vaults

Send Inquiry

(0/10)

clearall