Our UHF RFID seal sticker combines a G2IL+ EPC identity, printable white PET face and adhesive tamper-evident structure in a 139 × 40 mm format. It is designed for meter enclosures and equipment access points where field teams need electronic identification and visible evidence of seal removal.
UHF RFID Seal Sticker Specifications
Confirm the meter or equipment surface, protected seam, destination frequency, field reader and inspection procedure before production approval.
| Specification | Available Configuration | Deployment Requirement |
|---|---|---|
| Sticker dimensions | 139 × 40 × 0.1 mm | Measure the enclosure and seam area |
| Antenna dimensions | 83 × 35 mm | Keep the active area at the approved position |
| Chip | G2IL+ | Confirm reader and middleware compatibility |
| Protocol | ISO 18000-6C / EPC Gen2 | Match the regional UHF system |
| TID/UID | 64 bits | Define whether TID is captured at commissioning |
| EPC memory | 128 bits | Provide the meter or seal numbering structure |
| User memory | 0 bits | Store service records in the backend |
| Reserve memory | 32-bit access and 32-bit kill passwords | Define password control and authorization |
| Operating frequency | 860–960 MHz | Confirm the destination-country band |
| Reference read range | Up to 300 cm in free air | Validate the installed meter environment |
| Face material | Printable white PET | Approve print and environmental durability |
| Installation | Adhesive, listed for on-metal use | Test the exact metal and surface coating |
Choose the Meter Sealing Point
The sticker should bridge a controlled opening without covering the meter display, regulatory markings, terminals or required service information.
Main Meter Cover
Bridge the housing and removable cover so authorized access produces an inspectable change.
Terminal Cover
Protect the selected terminal access point without placing the sticker over unsafe or prohibited areas.
Cabinet Door
Apply across a metal cabinet seam when the protected boundary is larger than the individual meter.
Service Panel
Identify the panel and record authorized opening during maintenance, inspection or component replacement.
Instrument Housing
Seal a calibration or configuration access point after testing the specific enclosure geometry.
Protective Package
Apply to an outer package when direct installation on the equipment is unsuitable for the required workflow.
Commission Stickers Before Field Installation
Allocate
Assign a unique EPC according to the utility, region, meter type or project numbering rules.
Encode
Write the approved EPC and verify the tag before it is released to the installer.
Match
Associate the electronic identity with the printed serial and intended meter or equipment record.
Issue
Record which installer, team, service area or work order receives each commissioned sticker.
Build a Field Installation Record
| Installation Field | Required Information | Verification Method | Record Purpose |
|---|---|---|---|
| Meter identity | Meter number, type and customer or site reference | Compare visible data with the work order | Prevent installation on the wrong meter |
| Seal identity | EPC, TID when required and printed serial | Read and compare the applied sticker | Create the meter-to-seal relationship |
| Location | Site, route, cabinet or service area | Confirm against the assignment record | Support future inspection planning |
| Seal position | Approved access point and orientation | Photograph or installation-position code | Standardize later inspection |
| Installer | Technician, team and installation date | Work-order sign-off | Maintain installation accountability |
| Initial condition | Adhesion, visual condition and RFID result | Final field scan and inspection | Establish the acceptance baseline |
Organize Route-Based Meter Inspection
Prepare the Route
Load the expected meter and seal records for the area assigned to the field technician.
Identify the Site
Confirm the location and visible meter identity before interpreting an RFID response.
Read the Seal
Use the approved reader, distance and orientation for the installed enclosure configuration.
Inspect Physically
Check the sticker position, edges, printed serial and opening boundary rather than relying on RFID alone.
Classify the Result
Record the seal as intact, unreadable, damaged, missing, replaced or requiring investigation.
Close the Visit
Save the inspection result, technician, date, supporting evidence and required follow-up action.
Define Responses to Seal Conditions
| Observed Condition | Possible Interpretation | Field Action | System Update |
|---|---|---|---|
| Intact and readable | Seal matches the expected installation condition | Complete the routine inspection | Record the successful visit |
| Intact but unreadable | Reader, orientation or tag performance issue | Repeat the approved troubleshooting process | Do not classify as tampering automatically |
| Visibly damaged | Impact, aging, removal attempt or service activity | Inspect the access point and supporting records | Open an exception case |
| Seal missing | Removal, replacement or incorrect installation record | Verify the meter and investigate the history | Do not issue a new seal without authorization |
| Different EPC present | Authorized replacement or record mismatch | Check the work order and replacement authorization | Reconcile old and new identities |
| Authorized opening | Approved maintenance or meter replacement | Close the previous seal record | Assign and verify a new sticker |
Validate On-Metal Installation
The model is listed for use on metal, but actual performance depends on the enclosure geometry, coating, nearby components and reader orientation.
Metal Type
Test the exact steel, aluminum or other substrate used for the meter or equipment housing.
Surface Coating
Check powder coating, paint, texture, corrosion, cleaning agents and surface contamination.
Housing Geometry
Evaluate curves, raised edges, recessed panels and the transition across the protected seam.
Reader Orientation
Record the approved scanning direction and distance for common field-access conditions.
Nearby Meters
Check whether adjacent tagged meters are captured when technicians intend to inspect one device.
Removal Result
Test the physical and electronic response after peeling, cutting or opening the protected cover.
Printing, Encoding and Field Identification
Visible Printing
- Utility or operator name
- Seal and meter reference
- Barcode or QR code
- Inspection and warning text
RFID Configuration
- Customer-defined EPC structure
- TID and EPC relationship
- Access-password requirement
- Kill-password requirement
Production Verification
- Duplicate EPC checking
- Print-to-encoding comparison
- RFID functionality test
- Finished data-file output
Information Needed for Configuration
Meter and Installation Details
- Meter or equipment type
- Metal, coating and surface texture
- Protected cover or enclosure seam
- Indoor or outdoor environment
- Installation and inspection procedure
RFID and Order Details
- Destination country and UHF band
- Field reader and antenna models
- EPC and password requirements
- Artwork and variable-data file
- Quantity and delivery destination
Related UHF Security Stickers
Compare surface compatibility, frequency, removal behavior, reader distance and inspection workflow before selecting another seal format.
UHF RFID Seal Sticker Questions
The product is listed for on-metal use, but the actual metal, coating, curvature, installation position and reader configuration must be tested together.
No. An unreadable result can also be caused by reader setup, orientation, interference or damage. Physical inspection and service records are required before classification.
The listed G2IL+ configuration has no user memory. Installation, inspection, maintenance and replacement history should be stored in a database linked to the EPC.
This passive UHF sticker has no battery or independent communication link. It is inspected visually or detected when compatible RFID equipment reads it.
No. Three meters is a reference free-air result. The metal enclosure, tag position, reader, antenna, power and nearby meters determine the installed range.
Close the original seal record, document the work order and removal reason, assign a new EPC, install the replacement and verify the new relationship.
Please provide the meter type, metal and coating, protected seam, operating environment, destination country, reader models, EPC rules, artwork, quantity and delivery destination.
Configure UHF Seal Stickers for Field Inspection
Send us the meter or equipment details, metal surface, protected seam, field environment, destination frequency, reader equipment, EPC format, artwork and quantity for review and pricing.
Request a UHF Seal Sticker ReviewHot Tags: uhf rfid seal sticker, China uhf rfid seal sticker manufacturers, suppliers, factory, rfid seal for cables, rfid seal for composting, rfid seal for fish, rfid seal for insulation materials, rfid seal for intrusion detection systems, rfid seal for vaults